GYFTY Non-me<x>tallic Strength Member Non-armored Cable
D1411 Brand Name:VCOM Outdoor Fiber Optic CableNon-me<x>tallic Strength Member Non-armored Loose Tube G652DSinglemoleFRP central
Price: $0In stock
Quantity 1 2+
Your Price 0 0
GYFTY Non-me<x>tallic Strength Member Non-armored Cable

D1411 Brand Name:VCOM Outdoor Fiber Optic CableNon-me<x>tallic Strength Member Non-armored Loose Tube G652DSinglemoleFRP central

GYFTY Non-me<x>tallic Strength Member Non-armored Cable
$0
Quantity:1
Features

N/A

Specifications

Cross Section Drawing  
 
Mechanical Specifications  
Cable Type              Loose tube
Number of fiber       24-144core
Fiber Type               OS2/ G652D
Filling rope               4-0
Moisture Barrier       Water blocking system
Loose tube and Filler elements: PBT, Ф2.2mm+-0.2mm
Central strength member: FRP, Ф2.0mm+-0.2mm
Outer sheath            PE,black
Bending radius(Static/ Dynamic): 10D/20D of the cable
Tensile Strength(Long/Short Term N): 400/1000
Crush Resistance(Long/Short Term N): 300/1000
Environmental Specifications  
Working  Temperature      -40 °C to  +70 °C
Installation Temperature   -15 °C to  +60 °C
Storage  Temperature      -40 °C to +70 °C
Fiber characteristics

Fiber styleUnitSM G652DMM 50/125MM 62.5/125
Conditionmm1310/1550850/1300850/1300
AttenuationdB/km≤0.36/0.23≤3.0/1.0≤3.0/1.0
Cladding diameterum125±1125±1125±1
Cladding non-circularity%≤1.0≤1.0≤1.0
Coating diameterum242±7242±7242±7

 
Complies with Standard:
YD/T 901-2001as well as IEC 60794-1.


N/A

Specifications

Cross Section Drawing  
 
Mechanical Specifications  
Cable Type              Loose tube
Number of fiber       24-144core
Fiber Type               OS2/ G652D
Filling rope               4-0
Moisture Barrier       Water blocking system
Loose tube and Filler elements: PBT, Ф2.2mm+-0.2mm
Central strength member: FRP, Ф2.0mm+-0.2mm
Outer sheath            PE,black
Bending radius(Static/ Dynamic): 10D/20D of the cable
Tensile Strength(Long/Short Term N): 400/1000
Crush Resistance(Long/Short Term N): 300/1000
Environmental Specifications  
Working  Temperature      -40 °C to  +70 °C
Installation Temperature   -15 °C to  +60 °C
Storage  Temperature      -40 °C to +70 °C
Fiber characteristics

Fiber styleUnitSM G652DMM 50/125MM 62.5/125
Conditionmm1310/1550850/1300850/1300
AttenuationdB/km≤0.36/0.23≤3.0/1.0≤3.0/1.0
Cladding diameterum125±1125±1125±1
Cladding non-circularity%≤1.0≤1.0≤1.0
Coating diameterum242±7242±7242±7

 
Complies with Standard:
YD/T 901-2001as well as IEC 60794-1.